MICROELECTRONICS SYSTEM LABORATORY

Microelectronics System Laboratory

Microelectronics Systems Laboratory (MSL) used for Electronics Systems Design, Development and Testing from MAV/UAV as well as for Aircraft. MSL equipped with design facilities and equipment that are used in the design flow from Requirements to Documentation for any system.

Specifications:

Trinocular PCB Inspection

  • 40 to 160x Magnification
  • 20x Wide-Angle Eyepiece
  • Max Specimen Height: approx 120mm
  • Lighting: 12V 10W halogen bulb
  • Eye Sepration Adjustment: 57-75 mm
  • PC Interface

MICROELECTRONICS SYSTEM LABORATORY1

 

RF Analysis

  • Frequency: 1MHz - 13,6 GHz
  • Handheld
  • RBW : 10Hz - 3 MHz (1-3-10 Sequence)
  • VBW : 1Hz - 3 MHz (1-3-10 Sequence)
  • DANL: +10 dBm (1 to 500 MHz)
  • DANL : +20 dBm (500 MHz to 13.6 GHz)
  • Connector and impedance: Type-N female, 50 Ω

RF Analysis

 

High BW Signal Analysis

  • 4 Channel Mixed Signal Oscillscope
  • 4 GSa /s Real Time, Low Noise Flash A /D Converter
  • Time and Frequency Domain Analysis
  • Real-Time FFT (dBm, dBV, Vrms), up to 64 kPts
  • Trigerring (Auto, Normal, Single)
  • Serial Bus Trigger and Hardware accelerated Decode
    including List View. Options: I2C + SPI + UART/RS-232 (HOO10/HOO11), CAN + LIN (HOO12)
  • Automatic Search for user-defined Events
  • Pass/Fail Test based on Masks

High BW Signal Analysis

 

Digital Protocol Analysis

  • Length & Width: 3.12 inch (79.2mm)
  • Input voltage range: -0.9V to 6V
  • Available Sampling Rates: 250 kHz to 100 MHz
  • Sample Depth : Upto 10B Samples
  • Pulse-width measurement: +/- 10ns @ 100MHz, +/- 20ns @ 50MHz, +/- 40ns @ 25MHz, +/- 80ns @ 12.5MHz
  • Max Input Bandwidt : 25MHz square wave

Digital Protocol Analysis

 

GCS Integration and Test

  • Integration and Testing in Lab
  • Easy Modification and Implementation
  • Quick Parameter Tuning
  • RC and Communication Checking
  • Open Source and Custom GCS

 GCS Integration and Test

 

Pressure Chamber Calibration Bench

  • Range: 0 to 15000 ft
  • Rate of Climb : 1000 ft/min
  • Input: 1013.25 mbar to 571.8 mbar
  • Custom Build Pressure chamber
  • Useful for Sensor Calibration used in MAVs
  • Data Logger and Anlaysis software
  • Small in footprint

 Pressure Chamber Calibration Bench

 

Close Field Analysis

  • Different Frequency Band Near Field Probe Set
  • Electric and Magnetic Field Measurement
  • Spectrum Analyzer Interface
  • Hardware Level Checking for Interference

 Close Field Analysis

 

Other facilities are listed below:

  • Sensor Integration and Test Station
  • Autopilot Development Station
  • RC Communication Test Station
  • Digital Rework Station
  • Engineering Tool Kits Station
  • Flight Control Test Station
  • Thermal Measurements Station

microelectronics-system7

Techniques applied in this facility

Techniques applied in this facility

Major clients of this facility: Internal design and development

Last updated on : 27-09-2020 03:18:30pm